ArrowArrow education > U.L. ratings

U.L. Listings

To find the most current listings see: http://www.ul.com . This is an important step.  Always double check with UL as specifications do change...

Most all our foams cary an HBF rating.  HF-1 and HF-2 are "fire retardent".  The V rating usually applys to injection molded plastics (hard plastic not foam). H designates a "horizontal" test and V is "vertiical".


Criteria Conditions

HF-1

HF-2

Afterflame time

4/5 is £ 2s
1/5 is £ 10s

4/5 is £ 2s
1/5 is £ 10s

Afterglow time for each individual specimen

£30s

£ 30s

Cotton indicator ignited by flaming particles or drops

No

Yes

Afterflame of afterglow of any specimen up to the holding clamp

< 60mm

< 60mm

Notes: 4/5 - Four out of a set of five specimens
1/5 – One out of a set of five specimens.


Criteria Conditions

V-0

V-1

V-2

Afterflame time for each specimen t1 or t2

£ 10s

£ 30s

£30s

Total afterflame time for any condition set (t1 plus t2 for the 5 specimens)

£ 50s

£ 250s

£ 250s

Afterflame plus afterglow time for each individual specimen after the second flame application (t1 + t2)

£ 30s

£ 60s

£ 60s

Afterflame of afterglow of any specimen up to the holding clamp

No

No

No

Cotton indicator ignited by flaming or drops

No

No

Yes


Afterflame, when the flame ceases.
Afterglow, when the flaming and glowing ceases.

 
  Horizontal Line